3 Definitions, symbols and abbreviations
25.4023GPPRelease 17Synchronisation in UTRAN Stage 2TS
3.1 Definitions
Network Synchronisation: generic concept that depicts the way of distributing a common frequency to all elements in a network
Reference Timing Signal: as defined in reference ITU-T Rec. G.810 [28].
Holdover mode: operating condition of a clock which has lost its controlling reference input and is using stored data, acquired while in locked operation (that is while controlled by an external input reference), to control its output. The stored data are used to control phase and frequency variations, allowing the locked condition to be reproduced within specifications.
3.2 Symbols
No special symbols are defined in this document.
3.3 Abbreviations
For the purposes of the present document, the following abbreviations apply:
ACK (time alignment) acknowledgement
BFN Node B Frame Number (counter)
CFN Connection Frame Number (counter)
CH Channel
CN Core Network
CPICH Common Pilot Channel
CRNC Controlling RNC
DL Down Link
DCH Dedicated Channel
DOFFFDD FDD Default DPCH Offset value
DOFFTDD TDD Default DPCH Offset value
DPCH Dedicated Physical Channel
DPCCH Dedicated Physical Control Channel
DRNC Drift RNC
DSCH Downlink Shared Channel
FACH Forward Access Channel
FDD Frequency Division Duplex
F-DPCH Fractional DPCH
GPS Global Positioning System
HO Handover
IMB Integrated Mobile Broadcast
LTOA Latest Time of Arrival
L1 Layer 1
L2 Layer 2
MAC Medium Access Control
MBMS Multimedia Broadcast Multicast Service
MBSFN Multicast/Broadcast over a Single Frequency Network
MCCH MBMS point-to-multipoint Control Channel
MFN Multicast Frame Number (counter)
MTCH MBMS point-to-multipoint Traffic Channel
NACK (time alignment) negative acknowledgement
PCCPCH Primary Common Control Physical Channel
PCH Paging Channel
PDU Packet Data Unit
PTP Point-to-Point
PTM Point-to-Multipoint
PUSCH Physical Uplink Shared Channel
RAB Radio Access Bearer
RACH Random Access Channel
RAN Radio Access Network
RFN RNC Frame Number (counter)
RL Radio Link
RNC Radio Network Controller
RNS Radio Network Subsystem
RRC Radio Resource Control
SAP Service Access Point
SCH Synchronisation Channel
SFN Cell System Frame Number (counter)
SRNC Serving RNC
SRNS Serving RNS
TBS Transport Block Set
TDD Time Division Duplex
TOA Time Of Arrival
TOAWE Time Of Arrival Window Endpoint
TOAWS Time Of Arrival Window Startpoint
TTI Time Transmission Interval
UE User Equipment
UL Up Link
UMTS Universal Mobile Telecommunications System
USCH Uplink Shared CHannel
UTRAN UMTS Terrestrial Radio Access Network
3.4 Specification Notations
For the purposes of the present document, the following notations apply:
[FDD] This tagging of a word indicates that the word preceding the tag "[FDD]" applies only to FDD. This tagging of a heading indicates that the heading preceding the tag "[FDD]" and the section following the heading applies only to FDD.
[TDD] This tagging of a word indicates that the word preceding the tag "[TDD]" applies only to TDD, including 3.84Mcps TDD, 7.68Mcps TDD and 1.28Mcps TDD. This tagging of a heading indicates that the heading preceding the tag "[TDD]" and the section following the heading applies only to TDD, including 3.84Mcps TDD, 7.68Mcps TDD and 1.28Mcps TDD.
[3.84Mcps TDD] This tagging of a word indicates that the word preceding the tag "[3.84Mcps TDD]" applies only to 3.84Mcps TDD. This tagging of a heading indicates that the heading preceding the tag "[3.84Mcps TDD]" and the section following the heading applies only to 3.84Mcps TDD.
[1.28Mcps TDD] This tagging of a word indicates that the word preceding the tag "[1.28Mcps TDD]" applies only to 1.28Mcps TDD. This tagging of a heading indicates that the heading preceding the tag "[1.28Mcps TDD]" and the section following the heading applies only to 1.28Mcps TDD.
[7.68Mcps TDD] This tagging of a word indicates that the word preceding the tag "[7.68Mcps TDD]" applies only to 7.68Mcps TDD. This tagging of a heading indicates that the heading preceding the tag "[7.68Mcps TDD]" and the section following the heading applies only to 7.68Mcps TDD.
[FDD – …] This tagging indicates that the enclosed text following the "[FDD – " applies only to FDD. Multiple sequential paragraphs applying only to FDD are enclosed separately to enable insertion of TDD specific (or common) paragraphs between the FDD specific paragraphs.
[TDD – …] This tagging indicates that the enclosed text following the "[TDD – " applies only to TDD including 3.84Mcps TDD, 7.68Mcps TDD and 1.28Mcps TDD. Multiple sequential paragraphs applying only to TDD are enclosed separately to enable insertion of FDD specific (or common) paragraphs between the TDD specific paragraphs.
[3.84Mcps TDD – …] This tagging indicates that the enclosed text following the "[3.84Mcps TDD – " applies only to 3.84Mcps TDD. Multiple sequential paragraphs applying only to 3.84Mcps TDD are enclosed separately to enable insertion of FDD and TDD specific (or common) paragraphs between the 3.84Mcps TDD specific paragraphs.
[1.28Mcps TDD – …] This tagging indicates that the enclosed text following the "[1.28Mcps TDD – " applies only to 1.28Mcps TDD. Multiple sequential paragraphs applying only to 1.28Mcps TDD are enclosed separately to enable insertion of FDD and TDD specific (or common) paragraphs between the 1.28Mcps TDD specific paragraphs.
[7.68Mcps TDD – …] This tagging indicates that the enclosed text following the "[7.68Mcps TDD – " applies only to 7.68Mcps TDD. Multiple sequential paragraphs applying only to 7.68Mcps TDD are enclosed separately to enable insertion of FDD and TDD specific (or common) paragraphs between the 7.68Mcps TDD specific paragraphs.
Procedure When referring to an elementary procedure in the specification, the Procedure Name is written with the first letters in each word in upper case characters followed by the word "procedure", e.g. Radio Link Setup procedure.
Message When referring to a message in the specification, the MESSAGE NAME is written with all letters in upper case characters followed by the word "message", e.g. RADIO LINK SETUP REQUEST message.
IE When referring to an information element (IE) in the specification, the Information Element Name is written with the first letters in each word in upper case characters and all letters in Italic font followed by the abbreviation "IE", e.g. Transport Format Set IE.
Value of an IE When referring to the value of an information element (IE) in the specification, the "Value" is enclosed by quotation marks, e.g. "Abstract Syntax Error (Reject)".
Frame When referring to a control or data frame in the specification, the CONTROL/DATA FRAME NAME is written with all letters in upper case characters followed by the words "control/data frame", e.g. FACH FLOW CONTROL control frame.