B.3 Moving propagation conditions

25.1043GPPBase Station (BS) radio transmission and reception (FDD)Release 17TS

The dynamic propagation conditions for the test of the base band performance are non-fading channel models with two taps. The moving propagation condition has two tap, one static, Path0, and one moving, Path1. The time difference between the two paths is according Equation (B.1). The parameters for the equation are shown in Table B.2. The taps have equal strengths and equal phases.

Figure B.1: The moving propagation conditions

(B.1)

Table B.2: Parameters for moving propagation

Parameter

Value

A

5 μs

B

1 μs

ω